HEAT PUMPS

A Heat Pump is a device that uses a small amount of energy available in the atmosphere to move heat from one location to another which is energy-efficient and affordable. The new generation of heat pumps can deliver heat even in extreme conditions, with advanced systems rated as low as 30 degrees below zero.
These can also be connected to the hot water storage tanks of existing water heating systems. Particularly when connected to solar water heating systems, huge energy savings can be achieved. The heat pump can be utilized either as the main source for water heating or as a backup system without disturbing the running condition of the existing one.

How does a Supreme Heat Pumps Works?

It works on the principle of four phases of the reversed Carnot cycle. Major components of a Heat Pump Water Heaters include a compressor, a refrigerant, two heat exchangers (a condenser and an evaporator) and an expansion value.
Evaporator : It contains a liquid refrigerant which evaporates to gas and extracts heat from ambient air which is used to evaporate the water.
Condenser: It compresses the fluid and increases its temperature which releases heat by condensing the refrigerant.
Expansion: It reduces the pressure and temperature of the process fluid to below the level of outside air temperature in order to restart the cycle.

SUPREME HEAT PUMPS SPECIFICATIONS

Horizontal discharge Heat Pump

Technical Data:
Model NumberSPHP-4KS-07SPHP-5KS-07SPHP-7KS-07SPHP-9KS-07SPHP-13KS-07SPHP-17KS-07
Heating CapacitykW4.14.86.89.513.217.5
Power InputkW1.011.221.732.473.324.5
COP4.063.933.933.853.973.89
Power SupplyV/Ph/Hz220-240/1/50220-240/1/50220-240/1/50220-240/1/50380-415/3/50380-415/3/50
Compressor TypeN/ARotaryRotaryRotaryRotaryScrollScroll
Compressor Quantitypc111111
Water PumpN/AWiloWiloWiloWilo
Water Pump QuantityN/A111100
Fan TypeN/AAxialAxialAxialAxialAxialAxial
Fan Quantitypc111111
RefrigerantN/AR407CR407CR407CR407CR407CR407C
Refrigerant ControlN/AElectronic Expansion Valve
DefrostingN/AFour way valve reverse defrosting
Nominal Water Flowm3/h0.8511.422.83.86
Water ConnectionInch111111
Sound LeveldB(A)505050545556
Max Water Temprature°C606060606060
Outdoor Temp.Operating limits°CMin:10/Max:+43
Degree of ProtectionN/AIPX4IPX4IPX4IPX4IPX4IPX4
Weightkg47515576107160
Lengthmm8908908909409801080
Widthmm360360360410500600
Heightmm6006006008009501210

Test Condition:(1)Air Temperature DB/WB=20°C, initial/final water temperature=15°C/55°

Vertical discharge Heat Pump

Technical Data:
Model NumberSPHP-13KT-07SPHP-17KT-07SPHP-20KT-07SPHP-41KT-07SPHP-070HTSPHP-150HT
Heating CapacitykW12.816.620.1411223
Power InputkW3.264.255.1310.7510.7510.75
COP3.933.903.923.822.802.80
Power SupplyV/Ph/Hz380-415/3/50380-415/3/50380-415/3/50380-415/3/50380-415/3/50380-415/3/50
Compressor TypeN/AScrollScrollScrollScrollScrollScroll
Compressor Quantitypc111221
Fan TypeN/AAxialAxialAxialAxialAxialAxial
Fan Quantitypc111221
RefrigerantN/AR407CR407CR407CR407CR134AR134A
Refrigerant ControlN/AElectronic Expansion Valve
DefrostingN/AFour way valve reverse defrosting
Nominal Water Flowm3/h2.63.44.28.54.26.7
Water ConnectionInch1111.51.51
Sound LeveldB(A)565656606056
Max Water Temprature°C606060608080
Outdoor Temp.Operating limits°CMin:10/Max:+43
Degree of ProtectionN/AIPX4IPX4IPX4IPX4IPX4IPX4
Weightkg101132148245245148
Lengthmm82082082015001500820
Widthmm700700700750750700
Heightmm87010801380108010801380

Test Condition:(1)Air Temperature DB/WB=20°C, initial/final water temperature=15°C/55°

We use cookies in order to give you the best possible experience on our website. By continuing to use this site, you agree to our use of cookies.